This section lists the VEP4600 specifications.
CAUTION: Operate the product at an ambient temperature not higher than 0°C to 45°C (32°F to 113°F).
CAUTION: Lithium Battery Caution: There is a danger of explosion if the battery is incorrectly replaced. Replace only
with same or equivalent type of battery. Dispose of the batteries according to the manufacturer's instructions.
NOTE: For RoHS information, see Restricted Material Compliance.
Topics:
Chassis physical design
VEP4600 Expansion Card antennas
Agency compliance
Chassis physical design
Table 1. Chassis physical design
Parameter Specifications
Height 1.72 inches (43.6 mm)
Width 17.1 inches (434 mm)
Depth
15 inches (381 mm)
PSU/fan tray handle: 1.57 inches (40 mm)
Chassis weight with factory-installed components
16.40lbs (7.43 kg), (2 PSUs, and 5 fans, 1 rNDC card)
Rack clearance required
Front: 5 inches (12.7 cm)
Back: 5 inches (12.7 cm)
Table 2. Environmental parameters
Parameter Specifications
Operating temperature 0°C to 45°C (32°F to 113°F) continuously
NOTE: Reduce maximum temperature by 1°C/125
meters (1°F/228 feet) above 950 meters (3,117 feet).
Operating humidity 5% to 85% (RH), non-condensing, continuously
5% to 90% (RH), non-condensing, short term
Short term is </= 1% of operational hours per year.
Storage temperature –40°F to 70°C (–40°F to 158°F)
Storage humidity 5% to 95%, non-condensing
Maximum thermal output 311W = 1061 BTU/hr
Maximum operational altitude 10,000 feet (3,048 meters)
Maximum non-operational altitude 39,370 feet (12,000 meters)
Shock SV0115 — ODM
4
Specifications 13