Users Guide
• Response data byte 2—Reservation ID, LS byte 0000h reserved.
• Response data byte 3—Reservation ID, SM byte
Get SEL command
• Request data byte 1:2—Reservation IS, LS byte rst. Only required for a partial get. Otherwise use 0000h.
• Request data byte 3:4—SEL record ID, LS byte rst.
– 0000h=GET FIRST ENTRY
– FFFFh=GET LAST ENTRY
• Request data byte 5—Oset into record
• Request data byte 6—Bytes to read. FFH means read entire record.
• Response data byte 1—Completion code. Returns an error completion code if the SEL is empty.
– 81h=cannot execute the command, SEL erase in progress.
• Response data byte 2:3—Next SEL record ID. LS byte rst (returns FFFFh if the record just returned is the last record).
–
NOTE: FFFFh is not allowed as the record ID of an actual record. For example, the record ID in Record Data for the
last record cannot be FFFFh.
• Response data byte 4:N—Record data, 16 bytes for the entire record.
Set LOG conguration command
To set the system or audit log conguration, use the set LOG configuration command.
• Netfn—0x32
• Command—0x68
Audit log conguration
• Request data byte 1—Cmd
– [7:2] Reserved
– [1:0] 01h–Audit log
• Request data byte 1—Status
– [7:2] Reserved
– [1:0] 01h–Disabled
– 01h–Enable local
• Response data byte 1—00h-success
– CCh=invalid data eld
– FFh=unspecied error
• Response data byte 1—Cmd
– [7:2] Reserved
– [1:0] 00h–system log
• Response data byte 2—Status
– [7:2] Reserved
– [1:0] 01h–Disabled
– 01h–Enable local
• Response data byte 3-70 for REMOTE (68 bytes) or 3-7 for LOCAL (5 bytes)—ENABLED REMOTE
Conguration
methods 73