Install Guide

Run the Unified Firmware Updater through USB
1. From mounted USB, run the Unified Firmware Updater with the following commands:
a. root@dellemc-diag-os:~# cd /mnt/usb
b. root@dellemc-diag-os:/mnt/usb# chmod 777 vep4600_ufw_x.x
c. root@dellemc-diag-os:/mnt/usb# ./vep4600_ufw_x.x interactive
2. The following menu is displayed below:
root@dellemc-diag-os:/mnt/usb# chmod 777 vep4600_ufw_x.x
root@dellemc-diag-os:/mnt/usb# ./vep4600_ufw_x.x interactive
Creating directory images
Verifying archive integrity... 100% MD5 checksums are OK. All good.
Uncompressing release 100%
Selecting previously unselected package zlib1g-dev:amd64.
(Reading database ... 20150 files and directories currently installed.)
Preparing to unpack .../zlib1g-dev_1%3a1.x.x.dfsg-2+b1_amd64.deb ...
Unpacking zlib1g-dev:amd64 (1:1.x.x.dfsg-2+b1) ...
Setting up zlib1g-dev:amd64 (1:1.x.x.dfsg-2+b1) ...
Processing triggers for man-db (2.7.0.2-5) ...
fopen: Permission denied
Selecting previously unselected package libssl-dev:amd64.
(Reading database ... 20181 files and directories currently installed.)
Preparing to unpack .../libssl-dev_1.0.1t-1+deb8u6_amd64.deb ...
Unpacking libssl-dev:amd64 (1.0.1t-1+deb8u6) ...
Setting up libssl-dev:amd64 (1.0.1t-1+deb8u6) ...
Selecting previously unselected package libssl-doc.
(Reading database ... 20267 files and directories currently installed.)
Preparing to unpack .../libssl-doc_1.0.1t-1+deb8u6_all.deb ...
Unpacking libssl-doc (1.0.1t-1+deb8u6) ...
Setting up libssl-doc (1.0.1t-1+deb8u6) ...
Processing triggers for man-db (2.7.0.2-5) ...
fopen: Permission denied
Selecting previously unselected package bc.
(Reading database ... 21629 files and directories currently installed.)
Preparing to unpack diag/bc_1.06.95-9_amd64.deb ...
Unpacking bc (1.06.95-9) ...
Setting up bc (1.06.95-9) ...
Processing triggers for man-db (2.7.0.2-5) ...
fopen: Permission denied
Package version: x.x
Packaged images:
BMC image: x.x
BIOS image: 3.41.0.x-xx
CPLD image: XxXX
Wifi CPLD image: XxX
Note:If BMC version is less than 1.23 CPLD versions will not be shown correctly
1. Automatically update all firmware components
2. BMC image[Primary version:x.x, backup version:1.23]
3. BIOS image[Booted version: 3.41.0.x-xx]
4. CPLD image[CPLD version: XxXX]
5. rNDC left CPLD image[CPLD version: 0x2]
6. rNDC right CPLD image[CPLD version: 0x2]
7. Intel rNDC firmware update[ left Type: X710, (18.8.9)]
[ right Type: X710, (18.8.9)]
q. Exit
Enter your choice:1
Upgrade firmware through DiagOS
13