VEP4600 Setup Guide
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2018 - 2019 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents 1 About this guide........................................................................................................................... 4 Related documents................................................................................................................................................................4 Information symbols..............................................................................................................................................................
1 About this guide This guide provides site preparation recommendations, step-by-step procedures for rack mounting and desk mounting, inserting modules, and connecting to a power source. CAUTION: To avoid electrostatic discharge (ESD) damage, wear grounding wrist straps when handling this equipment. NOTE: Only trained and qualified personnel can install this equipment. Read this guide before you install and power up this equipment. This equipment contains one power cable.
2 Site preparations VEP4600 is universal customer premise equipment (uCPE). To connect the service provider edge or enterprise branch to the cloud, use VEP4600 to host multiple virtual network functions (VNFs), such as SD-WAN, routing, firewall, and deep-packet inspection. For more information about VEP4600 specifications, see Chassis physical design section in this document. NOTE: Install the platform into a rack or cabinet before installing any optional components.
Rack mounting When you prepare your equipment rack, ensure that the rack is grounded. Ground the equipment rack to the same ground point the power service in your area uses. The ground path must be permanent. System ground Dell recommends grounding your system. Use VEP4600 in a CBN. Fans and airflow Fan installation is done as part of the factory install based on stock keeping unit (SKU) type. VEP 4600 supports an AC normal fan unit with fan airflow from the I/O to the PSU.
3 VEP4600 installation To install VEP4600, complete the installation procedures in the order presented in this section. Always handle the platform and its components with care. Avoid dropping the platform or any field replaceable units (FRUs). NOTE: ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the platform and its components.
CAUTION: Professional installation instructions: Products with WIFI and Bluetooth capabilities need to be installed by qualified personnel with RF and regulatory related knowledge. The general user shall not attempt to install or change any wireless settings. Ground cable To attach a ground cable to the switch, use the included two M3 ground lug bracket screws. The switch ships with the M3 ground lug bracket screws attached.
NOTE: Do not the use the mounted two-post rails as a shelf or a workplace. Rack mount safety considerations • • • • • • Rack loading—Overloading or uneven loading of racks may result in shelf or rack failure, possibly damaging the equipment and causing personal injury. Stabilize racks in a permanent location before loading begins. Mount the components starting at the bottom of the rack, then work to the top. Do not exceed your rack’s load rating.
Figure 4. Platfrom rail attachment 2. Repeat on the other side of the platform. 3. Attach the outer platform rails to the two-post rack rails using two user-supplied screws on each side. 4. After you install both rails, line up the platform rails with the installed rack rails. Slide the platform in until it is flush with the front of rack. About three inches before you fully insert your platform, the rail locking feature engages to keep the platform from inadvertently sliding out and falling. Figure 5.
Figure 6. Platform rail attachment 3. Repeat on the other side of the platform. 4. Attach the platform rails to the four-post rack rails using two user-supplied screws on each side. Figure 7. Platform four-post front installed 5. Slide the rear platform rail from the back to the front bracket. Secure with two user-supplied screws on each side. Figure 8.
Optics removal Remove an optic by pushing the tab on the optic and sliding the optic from the port. When removing optics with direct attach cables (DACs) from the port, pull the release tab firmly and steadily. Before pulling the release tab, you may need to gently push the optic into the port to ensure that it is seated properly. Do not jerk or tug repeatedly on the tab. Platform power-up Supply power to the VEP4600 after you mount it in a rack or cabinet. Reinspect your platform before power-up.
4 Specifications This section lists the VEP4600 specifications. CAUTION: Operate the product at an ambient temperature not higher than 0°C to 45°C (32°F to 113°F). CAUTION: Lithium Battery Caution: There is a danger of explosion if the battery is incorrectly replaced. Replace only with same or equivalent type of battery. Dispose of the batteries according to the manufacturer's instructions. NOTE: For RoHS information, see Restricted Material Compliance.
Table 3. AC power requirements Parameter Specifications Power supply 100–240 VAC 50/60 Hz Typical current draw per platform • • • 110VAC: 1.89A (16 core) 240VAC: 0.86 A (16 core) 110VAC: 1.5A (8 core ) 240VAC: 0.7A (8 core) 110VAC: 1.35A (4 core) 240VAC: 0.65A (4 core) Maximum power capability • • • 5-fan 16-core processor: 311W 4-fan 8-core processor: 230W 4-fan 4-core processor: 220W Typical power consumption • • • 5-fan 16-core processor: 206.
Whip antennas on the VEP4600 WIFI card All antennas should be articulated to upright position for optimal performance. There should not be large metal objects within a three foot radius of the antenna. 1. WIFI 1 2. BT/BLE 3.
Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. NOTE: The country code selection is for non-US model only and is not available to all US model. Per FCC regulation, all WiFi product marketed in US must fixed to US operation channels only.
4. The worst-case tilt angle(s) necessary to remain compliant with the eirp elevation mask requirement set forth in Section 6.2.2(3) shall be clearly indicated. 5. Users should also be advised that high-power radars are allocated as primary users (i.e. priority users) of the bands 5250-5350 MHz and 5650-5850 MHz and that these radars could cause interference and/or damage to LE-LAN devices. Avertissement: 1.
European Union EMC directive conformance statement This product is in conformity with the protection requirements of EU Council Directive 2004/108/EC on the approximation of the laws of the Member States relating to electromagnetic compatibility. Dell EMC cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended modification of this product, including the fitting of non-Dell EMC option cards.
BTE compliance certificate Japanese BTE compliance certificate Korean certification of compliance Korean certification of compliance Figure 9. Korean package label Radio compliance certificate Korea (Korean warning statement is only required for devices contain 2400~2483 and/or 5725~5825 MHz radios) 해당 무선설비는 운용 중 전파혼신 가능성이 있음 Korean radio compliance certificate Mexican certification of compliance Mexican compliance. La operación de este equipo está sujeta a las siguientes dos condiciones: 1.
Taiwanese certification of compliance Taiwanese radio compliance. 台灣: 國家通訊傳播委員會 低功率電波輻射性電機管理辦法 第十二條經型式認證合格之低功率射頻電機,非經許可,公司、商號或使 用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。 第十四條低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發 現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。 前項合法通信,指依電信法規定作業之 無線電通信。低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。 在 5.25-5.35 秭赫頻帶內操作之無線資訊傳輸設備,限於室內使用。 Taiwanese radio compliance certificate Thailand certification of compliance Thailand radio compliance.
XXXXXX (xxxxxx = Dealer Code) Certification pending.
5 Support The support site provides documents and tools to help you effectively use your equipment and mitigate network outages. Through the support site you can obtain technical information, access software upgrades and patches, download available management software, and manage your open cases. The support site provides integrated, secure access to these services. To access the support site, go to www.dell.com/support/.