Setup Guide

Optics removal
Remove an optic by pushing the tab on the optic and sliding the optic from the port.
When removing optics with direct attach cables (DACs) from the port, pull the release tab firmly and steadily. Before pulling the release
tab, you may need to gently push the optic into the port to ensure that it is seated properly. Do not jerk or tug repeatedly on the tab.
Platform power-up
Supply power to the VEP4600 after you mount it in a rack or cabinet.
Reinspect your platform before power-up. Verify the following:
The equipment is properly secured to the rack. Dell EMC recommends properly grounding the platform.
The ambient temperature around the unit, which may be higher than the room temperature, is within the limits specified for the
VEP4600, see
Specifications.
There is sufficient airflow around the unit.
The input circuits are correctly sized for the loads and that you use sufficient overcurrent protection devices.
All protective covers are in place.
Blank panels are installed if you do not install optional modules.
CAUTION:
Do not power up the platform if you did not install a fan module.
NOTE: A US AC power cable is included for powering up an AC power supply. You must order all other power cables
separately.
NOTE: ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap
when handling the platform and its components.
Power up sequence
When the platform powers up, the fans immediately come on at high speed. The fan speed slows as the platform continues to boot up.
12
VEP4600 installation