Users Guide

Access system health sensors
To check sensor information, use the following command:
root@dellemc-diag-os:~# ipmitool sensor list
To change the sensor threshold, see the IPMI Specication v2.0 chapter 35.8 Set Sensor Thresholds Command.
Request data byte 1—Sensor number, FFH=reserved
Request data byte 2
[7:6] - reserved. Write as 00b
[5] - 1b=set upper non-recoverable threshold
[4] - 1b=set upper critical threshold
[3] - 1b=set upper non-critical threshold
[2] - 1b=set lower non-recoverable threshold
[1] - 1b=set lower critical threshold
[0] - 1b=set lower non-critical threshold
Request data byte 3—lower non-critical threshold. Ignored if bit 0 of byte 2 = 0
Request data byte 4—lower critical threshold. Ignored if bit 1 of byte 2 = 0
Request data byte 5—lower non-recoverable threshold. Ignored if bit 2 of byte 2 = 0
Request data byte 6—upper non-critical threshold. Ignored if bit 3 of byte 2 = 0
Request data byte 7—upper critical threshold value. Ignored if bit 4 of byte 2 = 0
Request data byte 8—upper non-recoverable threshold value. Ignored if bit 5 of byte 2 = 0
Response data byte 1—Completion code
ipmitool sensors
-root@dellemc-diag-os:~# ipmitool sensor list
PSU2AF_temp | 27.000 | degrees C | cr | 24.000 | 29.000 | 34.000 | 41.000 |
60.000 | 68.000
PSU1AF_temp | 28.000 | degrees C | cr | 24.000 | 29.000 | 34.000 | 41.000 |
60.000 | 68.000
PT_Left_temp | 26.000 | degrees C | cr | 24.000 | 29.000 | 34.000 | 41.000 |
65.000 | 70.000
PT_Right_temp | 26.000 | degrees C | cr | 24.000 | 29.000 | 34.000 | 41.000 |
65.000 | 70.000
ILET_AF_temp | 27.000 | degrees C | cr | 24.000 | 29.000 | 34.000 | 41.000 |
60.000 | 68.000
CPU_Near_temp | 30.000 | degrees C | nc | 24.000 | 29.000 | 34.000 | 41.000 |
60.000 | 68.000
PT_Mid_temp | 32.000 | degrees C | nc | 24.000 | 29.000 | 34.000 | 41.000 |
80.000 | 85.000
NPU_Near_temp | 35.000 | degrees C | ok | 24.000 | 29.000 | 34.000 | 41.000 |
80.000 | 85.000
TC_Near_temp | 32.000 | degrees C | nc | 24.000 | 29.000 | 34.000 | 41.000 |
60.000 | 68.000
NPU_Mid_temp | 0.000 | degrees C | nr | 24.000 | 29.000 | 34.000 | 41.000 |
85.000 | 95.000
PSU1_Normal_temp | 39.000 | degrees C | ok | 24.000 | 29.000 | 34.000 | 41.000 |
80.000 | 85.000
PSU1_Sys_temp | 31.000 | degrees C | nc | 24.000 | 29.000 | 34.000 | 41.000 |
80.000 | 85.000
7
88 Access system health sensors