Administrator Guide

Table Of Contents
cfgRhostsSyslogServer2 (Read or Write)
Table 146. Details of cfgRhostsSyslogServer2
Description
To store the RAC and SEL logs Specify the second of three possible remote syslog servers. This property is
only valid if cfgRhostsSyslogEnable is set to 1 (enabled).
Legal Values
String from 0 to 63 characters.
Default
<blank>
cfgRhostsSyslogServer3 (Read or Write)
Table 147. Details of cfgRhostsSyslogServer3
Description
To store the RAC and SEL logs specify the third of three possible remote syslog servers. This property is
only valid if cfgRhostsSyslogEnable is set to 1(enabled).
Legal Values
String from 0 to 63 characters.
Default
<blank>
cfgUserAdmin
This group provides configuration information about the users allowed to access iDRAC through the available remote interfaces.
Up to 16 instances of the user group are allowed. Each instance represents the configuration for an individual user.
Use this object with the config or get subcommands. To use the command as follows: -i <index group>, supply an index
group number
The following sections provide information about the objects in the cfgUserAdmin group.
cfgUserAdminIndex (Read Only)
Table 148. Details of cfgUserAdminIndex
Description The unique index of a user.
Legal Values
This parameter is populated based on the existing instances.
Default
<index of the instance>
cfgUserAdminIpmiLanPrivilege (Read or Write)
Table 149. Details of cfgUserAdminIpmiLanPrivilege
Description The maximum privilege on the IPMI LAN channel.
Legal Values
2(User)
3(Operator)
4(Administrator)
15(No access)
Default
4(User 2)
15(All others)
iDRAC Property Database Group and Object Descriptions 173