Users Guide

Table Of Contents
RAID 60 characteristics:
Groups n*s disks as one large virtual disk with a capacity of s*(n-2) disks, where s is the number of spans and n is the
number of disks within each span.
Redundant information (parity) is alternately stored on all disks of each RAID 6 span.
Better read performance, but slower write performance.
Increased redundancy provides greater data protection than a RAID 50.
Requires proportionally as much parity information as RAID 6.
Two disks per span are required for parity. RAID 60 is more expensive in terms of disk space.
RAID level 10 - striped with mirrors
The RAB considers RAID level 10 to be an implementation of RAID level 1. RAID 10 combines mirrored physical disks (RAID 1)
with data striping (RAID 0). With RAID 10, data is striped across multiple physical disks. The striped disk group is then mirrored
onto another set of physical disks. RAID 10 can be considered a mirror of stripes.
Managing storage devices
227