Users Guide

Table Of Contents
Updating firmware using remote RACADM
1. Download the firmware image to the TFTP or FTP server. For example, C:\downloads\firmimg.d9
2. Run the following RACADM command:
TFTP server:
Using fwupdate command:
racadm -r <iDRAC IP address> -u <username> -p <password> fwupdate -g -u -a <path>
path
the location on the TFTP server where firmimg.d9 is stored.
Using update command:
racadm -r <iDRAC IP address> -u <username> -p <password> update f <filename>
FTP server:
Using fwupdate command:
racadm -r <iDRAC IP address> -u <username> -p <password> fwupdate f <ftpserver IP>
<ftpserver username> <ftpserver password> d <path>
path
the location on the FTP server where firmimg.d9 is stored.
Using update command:
racadm -r <iDRAC IP address> -u <username> -p <password> update f <filename>
For more information, see the iDRAC RACADM CLI Guide available at https://www.dell.com/idracmanuals.
Updating firmware using Lifecycle Controller Remote Services
For information to update the firmware using Lifecycle ControllerRemote Services, see Lifecycle Controller Remote Services
Quick Start Guide available at https://www.dell.com/idracmanuals.
Updating CMC firmware from iDRAC
In the PowerEdge FX2/FX2s chassis, you can update the firmware for the Chassis Management Controller and any component
that can be updated by CMC and shared by the servers from iDRAC.
Before applying the update, make sure that:
Servers are not allowed to power-up by CMC.
Chassis with LCD must display a message indicating update is in-progress.
Chassis without LCD must indicate the update progress using LED blinking pattern.
During the update, chassis action power commands are disabled.
The updates for components such as Programmable System-on-Chip (PSoC) of IOM that requires all the servers to be idle, the
update is applied on the next chassis power-up cycle.
CMC settings to update CMC firmware from iDRAC
In the PowerEdge FX2/FX2s chassis, before performing the firmware update from iDRAC for CMC and its shared components,
do the following:
1. Launch the CMC Web interface
2. Go to iDRAC Settings > Settings > CMC.
The Deploy iDRAC page is displayed.
3. From the Chassis Management at Server Mode , select Manage and Monitor, and the click Apply.
Setting up managed system
83