Users Guide

Table 10. Thermal Settings (continued)
Object Description Usage Example
FanSpeedHighOffsetVal
Getting this variable reads
the fan speed offset value
in %PWM for High Fan
Speed Offset setting.
This value depends on the
system.
Use FanSpeedOffset
object to set this value
using index value 1.
Values from 0-100
racadm get
system.thermalsetti
ngs
FanSpeedHighOffsetV
al
A numerical value, for example
66, is returned. This value
indicates that when you use
the following command, it
applies a fan speed offset of
High (66% PWM) over the
baseline fan speed
racadm set
system.thermalsetti
ngs FanSpeedOffset
1
FanSpeedLowOffsetVal
Getting this variable reads
the fan speed offset value
in %PWM for Low Fan
Speed Offset setting.
This value depends on the
system.
Use FanSpeedOffset
object to set this value
using index value 0.
Values from 0-100
racadm get
system.thermalsetti
ngs
FanSpeedLowOffsetVa
l
This returns a value such as
23. This means that when
you use the following
command, it applies a fan
speed offset of Low (23%
PWM) over baseline fan
speed
racadm set
system.thermalsetti
ngs FanSpeedOffset
0
FanSpeedMaxOffsetVal
Getting this variable reads
the fan speed offset value
in %PWM for Max Fan
Speed Offset setting.
This value depends on the
system.
Use FanSpeedOffset to
set this value using index
value 3
Values from 0-100
racadm get
system.thermalsetti
ngs
FanSpeedMaxOffsetVa
l
This returns a value such as
100. This means that when
you use the following
command, it applies a fan
speed offset of Max (meaning
full speed, 100% PWM).
Usually, this offset results in
fan speed increasing to full
speed.
racadm set
system.thermalsetti
ngs FanSpeedOffset
3
Setting up managed system 67