###################################################################### DELL(TM) ONLINE DIAGNOSTICS(OLD) VERSION 2.18 README ###################################################################### NOTE: This readme provides information about Dell Online Diagnostics version 2.18. For the latest version of the User’s Guide and Readme documentation, go to the Dell Support website at "support.dell.com/manuals", then click Software>Systems Management>Dell Online Diagnostics.
* SC420, SC430, SC1420, SC1425, SC1430, SC1435, SC440, 800, 830, 840, 850, 860, 1800, 1850, 1855MC, 2800, 2850, 6800, 6850, 1900, 1950, 1955, 2900, 2950, 6950, 2970, R805, M600, M605, T105, R900, R200, T605, R905, R300, T300, M805, M905, T100, R610, R710, T610, M610, M710, T410, R410, T710, T110, T310, R210, R510, R810, R910, M910, R310, R815, C1100, C1100 MLK, C2100, C6100, C6100 MLK, R715, M610x, M710HD, R415, R515, R210-II, T110-II and M915.
* Microsoft Windows Small Business Server 2003 R2 Standard and Premium editions with SP1 and SP2 * Microsoft Windows Server 2008 Standard, Enterprise, and Datacentre (x64) R2 SP1 editions * Microsoft Windows Essential Business Server 2008(x64) ---------------------------------------------------------------------GNU/Linux: * SUSE Linux Enterprise Server 11 with SP1(x86_64) * SUSE Linux Enterprise Server 10 with SP3(x86_64) * Red Hat Enterprise Linux 6 server (x86_64) * Red Hat Enterprise Linux 5 server (Upda
###################################################################### SETUP ###################################################################### * On Enterprise Linux operating systems (Red Hat, SUSE or VMware), unzip the tar.gz file to a desired location. The extracted files contain an install script (install.sh) and some Red Hat Package Manager (RPM) packages. Install the RPM packages using install.sh.
"Compatibility Arch Support package(s) [gtk, pango, and redhat-artwork] is not installed on this system. For details on installing the package(s) please refer to the README file." To resolve the issue, perform the following steps: 1. Run Red Hat Package Management Utility ("redhat-config-packages") 2. Select the "Compatibility Arch support" checkbox in the "Package Management" window and click "Details". 3. A new window ("Compatibility Arch Support Details") is displayed. 4.
application performance. If you are running critical applications that require rapid response or consume significant system resources, take appropriate precautions before running diagnostics. Close all non-essential applications and run diagnostics only during non-peak hours of system use. * Running multiple instances of Online Diagnostics is not supported. * Ensure that only Dell-supported USB devices are present in your system before running Online Diagnostics.
or RAID storage Manager to be installed for diagnostics to function. * Online Diagnostics does not support CERC SATA 2s (RAID mode). ====================================================================== NOTES FOR TAPE DRIVES, AUTOLOADERS, AND LIBRARIES ====================================================================== * The following table lists the supported Stand-alone drives and the tests.
--------------------|-----|-----|-----|-----|-----|-----|-----|------|-----| 122T LTO2 | S | NA | NA | S | S | S | S | S | S | --------------------|-----|-----|-----|-----|-----|-----|-----|------|-----| 124T VS160 | S | S | NA | S | S | S | S | S | S | --------------------|-----|-----|-----|-----|-----|-----|-----|------|-----| 124T LTO2-LC | S | S | NA | S | S | S | S | S | S | --------------------|-----|-----|-----|-----|-----|-----|-----|------|-----| 124T LTO3 | S | S | NA | S | S | S | S | S | S | ---
drive, one of the tests may fail and display the following message: "The DLL required to run the diagnostic is currently being used by another device. Retry the diagnostic after ensuring that the DLL is not being used by other devices." * Ensure that all tape backup services are stopped before executing tape diagnostics. Having tape backup services running while executing tape diagnostics may cause unpredictable behavior. The device may show unknown status when enumerated.
------------------------|---|-----|----|----|-----|-----| PowerVault-122T-SDLT320 | S | S | NA | S | S | S ------------------------|---|-----|----|----|-----|-----| PowerVault-122T-DLT-VS80| S | S | NA | S | NA | ------------------------|---|-----|----|----|-----|-----| PowerVault-132T-LTO2 | S | S | NA | S | S | S | ------------------------|---|-----|----|----|-----|-----| PowerVault-132T-LTO | S | S | NA | S | S | S | ------------------------|---|-----|----|----|-----|-----| PowerVault-132T-SDLT320 | S |
Some empty |All empty |All Full | Pass |Pass |"All IE | Some full | | | | | Full" | -----------|----------|-----------|------------|-------------|----------| Some empty |Some empty|All empty | Pass | Pass | Pass | Some full |Some full | | | | | -----------|----------|-----------|------------|-------------|----------| Some empty |Some empty|Some empty | Pass |Pass | Pass | Some full |Some full |Some full | | | | -----------|----------|-----------|------------|-------------|----------| Some empty |Some empty|
Adapter | | | | | |Test | -------------------|------|--------|------|---------|-----|--------| PRO/1000 MF | | | | | | | Server Adapter |Yes |Yes |Yes |Yes |No |Yes | -------------------|------|--------|------|---------|-----|--------| PRO/1000 MT | | | | | | | Server Adapter |Yes |Yes |Yes |Yes |Yes |Yes | -------------------|------|--------|------|---------|-----|--------| Intel PRO/1000 MT | | | | | | | Dual Port | | | | | | | Sever Adapter |Yes |Yes |Yes |Yes |Yes |Yes | --------------------------|-----
approximately 30 seconds for the adapter to return to an active state. If you start Online Diagnostics immediately after one of these situations, the diagnostic tests will not be listed. The workaround is to wait approximately 30 seconds before you start Online Diagnostics. * You may get unexpected results on disconnecting the USB cable while you are running a diskette test on a USB diskette drive. On systems running Red Hat Enterprise Linux products, the operating system may stop responding.
* When you run diagnostic tests or enumerate with "racadm racreset" command on a DRAC5 simultaneously, the device may not be enumerated or the test might fail in CLI/GUI. Wait until DRAC5 is reset and enumerate or run the tests again.
administrator”. * After running Online Diagnostics, the following errors are logged in the Event Viewer System Log by the Removable Storage Service. "Type: Error, Source: DCOM" "Type: Error, Source: Removable Storage Service" These entries are logged because Online Diagnostics stops the Removable Storage Service to scan the system for tape devices on which diagnostics are to be performed. After performing the scan, the Removable Storage Service restarts.
is the default browser. You can manually open the User's Guide available at "/docs//Users_Guide_HTML/index.htm". * On Japanese or Chinese Microsoft Windows operating systems, the device description of external USB devices may contain junk characters. If it is a non-Dell device, Dell recommends that the device should be disconnected before you start Online Diagnostics.
* Intel NIC Tests are available even if hardware is disabled from Windows Device Manager. * The SATA CD-DVD attached to the NVIDIA SATA controller is displayed under"System" in the tree view for operating systems released prior to Microsoft Windows Server 2008. * NIC Communication Test may fail if IPv6 is enabled.
before running the SCSI Communication test. * When the Yosemite backup software is installed on a system that has a tape changer, SCSI Communication tests and tape tests may fail. Ensure that the Yosemite backup software service is stopped before running these tests. * The Tape Self Test writes to and advances the tape media during execution. Manual erase operations using the Linux command "mt -f /dev/stX erase", if executed immediately after the Tape Self Test execution, will fail with an I/O error.
run Broadcom NIC test cases individually. * On 11G servers in absence AMEA card on iDRAC, upon starting OLD at command prompt(using startDiags.sh) or after running "rac" package at command prompt(using "pediags rac --show"), a NOTE is displayed which states "This Integrated Dell Remote Access Controller does not support RACADM commands. Please contact Dell Customer Service to upgrade your version of iDRAC". * On Linux, when you start Online Diagnostics using the /opt/dell/onlinediags/startDiags.
Tape Drives: • Dell PowerVault™ 100T DDS4 • Dell PowerVault 100T/114T DAT72 • Dell PowerVault 110T DLT1 • Dell PowerVault 110T VS80 • Dell PowerVault 110T/114T DLT VS160 • Dell PowerVault 110T SDLT 220 • Dell PowerVault 110T SDLT 320 • Dell PowerVault 110T LTO-2 • Dell PowerVault 110T/114T LTO-2-L • Dell PowerVault 110T/114T LTO-3 • Dell PowerVault 110T/114T LTO-3 - 060 • Dell PowerVault LTO-4 – 120 Tape Arrays, Autoloaders, and Libraries: • Dell PowerVault 122T-VS80 • Dell PowerVault 122T-SDLT 320 • Dell P
• PERC 4/IM • PERC 5/E • PERC 5/i Integrated • PERC 5/i Adapter • PERC 6/E • PERC 6/i Integrated • PERC 6/i Adapter • SW RAID S100 • SW RAID S300 a/m • PERC H200 i/a/m • PERC H700 i/a/m • PERC H800 • SAS 6Gbps HBA • SAS 5/E Adapter • SAS 5/iR Integrated • SAS 5/iR Adapter • SAS 5/i Integrated • SAS 6/iR Integrated • SAS 6/iR Adapter • SAS 6/iR Modular • ICH 7R • ESB2 SATA • CERC 6/I • CERC 6 /IM • CERC SATA 1.
to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own. March 2011 ###################################################################### “The software contained in the Online Diagnostics is an aggregate of third-party programs as well as Dell programs. Use of the software is subject to designated license terms. Refer to the LICENSE file for more information on third-party software license.