Administrator Guide
50 | Bare Metal Provisioning (BMP) - CLI
www.dell.com | support.dell.com
Command
History
Usage
Information
Check the currently configured Auto-Configuration mode (BMP or Normal reload)
on a switch running BMP using the
show reload-type command.
To display the current reload mode for BMP, use the
show bootvar or show system
brief
commands. The show bootvar command includes the path of the Dell
Networking OS image file retrieved from a DHCP server when BMP is running, but
not after you exit BMP.
Example Dell#show reload
reload-type : bmp [Next boot : bmp]
: enable
config-scr-download : enable
dhcp-timeout : 1
vendor-class-identifier : Device 609
retry-count : 3
Dell#
Related
Commands
reload-type — Configure the reload mode as BMP or Normal.
stop bmp
z
S5000, MXL
Switch
To prevent an infinite loop, stop the switch from reloading in BMP mode.
Syntax
stop bmp
Note: Replaces the stop jumpstart command.
Defaults
None.
Command Modes
EXEC
Version 9.6(0.0) Introduced on the S5000.
Version 9.5(0.1) Introduced on the Z9500.
Version 9.3(0.0) Updated the parameters for S6000.
Version 9.2(0.0) Introduced on the MXL Switch. Updated the parameters for S4810, S4820T, and
Z9000.
Version 9.1.0.0 Updated the parameters for S4810 and Z9000.
Version 9.0.2.0 Introduced on the S6000.
Version 9.0.0.0 Introduced in Z9000.
Version 8.3.19.0 Introduced on the S4820T.
Version 8.3.11.4 Introduced on the Z9000.
Version 8.3.10.0 Introduced on the S4810.