Service Manual

| +--ro bay-status? string
| +--ro fan-id? uint32
| +--ro fan-status? string
| +--ro fan-speed? uint32
+--ro environment-status* [unit-id]
| +--ro unit-id uint32
| +--ro unit-status? string
| +--ro temperature? int32
| +--ro voltage? voltage-status
| +--ro temp-status? uint32
+--ro thermal-sensor-reading* [unit-id]
+--ro unit-id uint32
+--ro sensor-class* [sensor-type]
+--ro sensor-type sensor-types
+--ro sensor* [sensor-id]
+--ro sensor-id uint32
+--ro temperature? int32
System Alarm
Use the following definition to display the Alarm entries:
Module: STATS
URI:
/api/operational/dell/stats/alarms
Methods
Supported:
GET
System Alarm Model
+--ro alarms
+--ro major-alarms [index]
| +--ro index uint32
| +--ro alarm-description? string
| +--ro duration? yang:timestamp
+--ro minor-alarms [index]
| +--ro index uint32
| +--ro alarm-description? string
| +--ro duration? yang:timestamp
+--ro alarm-thresholds [unit-number]
+--ro unit-number uint32
+--ro minor? uint32
+--ro minor-off? uint32
+--ro major? uint32
+--ro major-off? uint32
+--ro shutdown? uint32
System Inventory
The following definition displays the Inventory details:
Module: STATS
URI:
/api/operational/dell/stats/inventory
Methods
Supported:
GET
178
REST API