Setup Guide

config
VSN retrieves conguration information from the Hypervisor and implements any
necessary conguration changes automatically.
Defaults cong
Command Modes HYPERVISOR
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell EMC
Networking OS Command Line Reference Guide.
The following is a list of the Dell EMC Networking OS version history for this command.
Version Description
9.6(0.0) Introduced on the S5000.
9.2(0.0) Introduced on the MXL.
8.3.19.0 Introduced on the S4820T.
8.3.8.0 Introduced on the S4810.
Usage Information
You can use the mode command to change how virtual-server information is retrieved in an existing Hypervisor
session.
The following log messages display when you use the Hypervisor mode check option to retrieve conguration
information on virtual servers:
Dec 1 04:57:48: %STKUNIT0-M:CP %VSNMGR-5-VSN_VLAN_DISCOVERY: Te 0/35, Vlan:
4001-4008,4011-4012
Dec 1 04:56:46: %STKUNIT0-M:CP %VSNMGR-5-VSN_VLAN_WITHDRAWAL: Te 0/35, Vlan:
4001-4008,4011-4012
package install
Installs an Open Automation package, such as VSN. This command downloads the package from the specied location and installs it in the
internal ash memory on a switch.
S4810, S4820T, S5000, and MXL Switch
Syntax
package install location
Parameters
location
Enter the location where you want to install an Open Automation package, where location
is one of the following values:
flash://filename — Installs the VSN package le stored in ash memory on the
switch.
ftp://userid:password@host-ip-address/file-path — Logs in and
installs VSN from a le stored on an FTP server.
tftp://host-ip-address/file-path — Installs VSN from a le stored on a
TFTP server.
nfsmount://filepath — Copies from a le stored on an NFS mount le system.
128 Virtual Server Networking CLI