Setup Guide
• show reload-type — displays the current Reload mode (BMP mode or Normal mode).
relay
Allows you to congure the addition of option 82 in DHCP client packets.
S4810, S4820T, S3048–ON, S3100 series, S4048–ON,
S4048T–ON, S5000,
S5048F-ON, S6000, S6000–ON,
S6010–ON, S6100–ON, Z9100–ON, Z9500, C9010, IOA, FN-
IOM, and MXL
Syntax
relay { enable | disable | remote-id { hostname | MAC | Word }}
To reset the options 82 information, use the no relay { enable | disable | remote-id
{ hostname | MAC | Word }} command.
Parameters
enable
Enable the option 82 in BMP. The default value is the MAC address.
disable
Disable the option 82 in BMP.
remote-id
{ hostname |
MAC | Word }
Enter the keyword remote-id, then the hostname or chassis MAC address or a text
string to set as the remote ID in option 82. The default is the remote MAC ID for option
82.
Defaults none
Command Modes RELOAD-TYPE CONFIGURATION
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell EMC
Networking OS Command Line Reference Guide.
The following is a list of the Dell EMC Networking OS version history for this command.
Version Description
9.10(0.1) Introduced on the S4048T–ON and S6010–ON.
9.10(0.0) Introduced on the S6100–ON.
9.9(0.0) Introduced on the C9010.
9.8(2.0) Introduced on the S3100 series.
9.8(1.0P1) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048–ON.
9.8(0.0P2) Introduced on the S3048–ON.
9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, S6000–ON, Z9000, Z9500, IOA, and
MXL.
Related Commands
• reload-type — allows you to congure the reload-type options in reload-type sub command mode.
Bare Metal Provisioning CLI 45