Users Guide
Version Description
9.10(0.1) Introduced on the S4048T–ON and S6010–ON.
9.10(0.0) Introduced on the S6100–ON.
9.9(0.0) Introduced on the C9010.
9.8(2.0) Introduced on the S3100 series.
9.8(1.0P1) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048–ON.
9.8(0.0P2) Introduced on the S3048–ON.
9.7(0.0) Introduced on the S6000–ON.
9.6(0.0) Introduced on the S5000.
9.5(0.1) Introduced on the Z9500.
9.3(0.0) Introduced on the S6000.
9.2(0.0) Introduced on the MXL switch. Updated the parameters for S4810, S4820T, and Z9000.
9.1.0.0 Updated the parameters for S4810 and Z9000.
9.0.2.0 Introduced on the S6000.
9.0.0.0 Introduced on the Z9000.
8.3.19.0 Introduced on the S4820T.
8.3.11.4 Introduced on the Z9000.
8.3.10.0 Introduced on the S4810.
Usage Information
To check the currently congured Auto-Conguration mode (BMP or Normal reload) on a switch running BMP, use
the show reload-type command.
To display the current reload mode for BMP, use the show bootvar or show system brief commands. The
show bootvar command includes the path of the Dell EMC Networking OS image le retrieved from a DHCP
server when BMP is running, but not after you exit BMP.
Example
DellEMC#show reload
reload-type : bmp [Next boot : bmp]
: enable
config-scr-download : enable
dhcp-timeout : 1
vendor-class-identifier : Device 609
retry-count : 3
DellEMC#
Related Commands
reload-type — allows you to congure the reload-type options in reload-type sub command mode.
Bare Metal Provisioning CLI 53