Administrator Guide

To reset the options 82 information, use the no relay { enable | disable |
remote-id { hostname | MAC | Word }} command.
Parameters
enable
Enable the option 82 in BMP. The default value is the MAC
address.
disable
Disable the option 82 in BMP.
remote-id
{ hostname |
MAC | Word }
Enter the keyword remote-id, then the hostname or
chassis MAC address or a text string to set as the remote ID
in option 82. The default is the remote MAC ID for option 82.
Defaults none
Command
Modes
RELOAD-TYPE CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, Z9000,
Z9500, IOA, and MXL Switch.
Related
Commands
reload-type — allows you to configure the reload-type options in reload-type
sub command mode.
show reload-type — displays the current Reload mode (BMP mode or Normal
mode).
reload conditional nvram-cfg-change
After saving the BMP configuration, to perform a reload on the chassis due to configuration changes that
changes the NVRAM content, use this command.
S4810, S4820T, S5000, S6000, Z9000, Z9500 and MXL Switch
Syntax
reload conditional nvram-cfg-change
Defaults none
Command
Modes
EXEC
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
44