Owner's Manual

90 | Smart Scripting CLI
www.dell.com | support.dell.com
Defaults
None
Command Modes
CONFIGURATION
Command
History
Usage
Information
The maximum number of events you can configure is 20. The maximum number of
allowed tag patterns in a log event trigger is three. The tags of the log events must be
an exact comparison. The three tags work in a logical OR operation format (match
with any one of the tags occurs).
Related
Commands
Example
The following examples define triggers for the subsequent log messages: link down
pattern, failure pattern, severity 1 logs, and 85% memory consumption.
Example
“link down”
pattern in log
messages
Dell(conf)# script trigger-event ma_event log-event tag "Admin state to down: Ma"
Example
“failure” pattern
in log messages
Dell(conf)# script trigger-event fail_event log-event tag “failure”
Example
severity 1 log
messages
Dell(conf)# script trigger-event severity1_event log-event severity 1
Example
85% memory
consumption
Dell(conf)# script trigger-event memory_event mem-usage 85
show packages
Z9000
MXL Switch
Display the installed Open Automation packages, including version number and
contents.
Syntax
show packages [system]
Parameters
Defaults
None
Version 9.3(0.0) Introduced on the S6000.
Version 9.2(0.0) Introduced on the S4810, S4820T, Z9000 and MXL Switch.
Note: Before deleting a trigger event, the script must be unlinked from the event.
script execute triggered-by Configure the event that causes the script to execute.
system (Optional) Enter the keyword brief to display system information
about the package, version, and status of the package in all
stack-units.
Note: This option is only available on switches that allow
stacking.