Service Manual
Table Of Contents
- Dell Networking Open Automation Guide December 2015
- About this Guide
- Open Automation Framework
- Bare Metal Provisioning
- Introduction
- How it Works
- Prerequisites
- Industrial Standard Upgrades with BMP
- BMP Process Overview
- BMP Operations
- Configure BMP
- BMP Commands and Examples
- System Boot and Set-Up Behavior in BMP Mode
- BMP Mode: Boot and Set-UP Behavior
- DHCP Offer Vendor-Specific Option for BMP
- DHCP Offer Relay Option 82
- Software Upgrade Using BMP
- Apply Configurations Using BMP Scripts
- Using the Post-Configuration Script
- Using Auto-Execution Script (Normal Mode Only)
- Timers in Pre–configuration and Post–configuration Scripts
- Script Examples
- BMP Operations on Servers Overview
- File Server Settings
- Domain Name Server Settings
- BMP MIB Support
- Bare Metal Provisioning CLI
- Open Management Infrastructure
- Puppet
- Smart Scripting
- Overview
- Download the Smart Scripting Package
- Dell Proprietary Utilities
- Dell SmartScript Utilities
- SQLite
- NET SNMP Client
- Limits on System Usage
- Supported UNIX Utilities
- Creating a User Name and Password for Smart Scripting
- Logging in to a NetBSD UNIX Shell
- Downloading Scripts to a Switch
- Setting a Search Path for Scripts
- Scheduling and Executing Scripts
- Running a Script from the UNIX Shell
- Running Scripts with User Privileges
- Smart Scripting CLI
- disable
- execute
- mount nfs
- package install
- package uninstall
- script (run)
- script (stop/resume/clear/kill/unschedule)
- script event-handler
- script execute (EXEC mode)
- script execute (CONFIGURATION mode)
- script get
- script path
- script remove
- script trigger-event
- show packages
- show script
- start shell
- triggered-by
- switch script limit
- username (event handler)
- username
- Virtual Server Networking
- Virtual Server Networking CLI
- REST API
- HTTP and HTTPS
- XML
- Important Points to Remember
- REST Authentication
- Request Query Parameters
- Sample BGP Configurations
- HTTP Status Error Codes
- REST API — Protocol Data Unit (PDU) Structure
- Configurations
- Operational
- Operational Data for IPv6
- Management Information Base (MIB)
- IETF Interface Operations
- REST API Framework to Execute the CLIs
- Samples of the config-command
- Samples of the EXEC command
- Samples of the show-command
- REST API CLI
- Web Server with HTTP Support
Parameters
name
Enter up to 40 characters to specify the name of a
hypervisor session to which you want to connect on
network servers.
Defaults none
Command Modes HYPERVISOR
Command History
This guide is platform-specific. For command information about other platforms,
see the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.6(0.0) Introduced on the S5000.
9.2(0.0) Introduced on the MXL switch.
8.3.19.0 Introduced on the S4820T.
8.3.8.0 Introduced on the S4810.
Usage Information
To configure settings for the session, after you enter the command, you are placed
in Hypervisor Configuration mode.
To remove the configuration of a specified hypervisor session from the running
configuration and close active hypervisor sessions without removing the VSN agent
from the system, enter the no hypervisor name command.
mode
Set the Hypervisor mode used to retrieve configuration information on virtual servers.
S4810, S4820T, S5000, and MXL Switch
Syntax
[no] mode {check | config}
Parameters
check
VSN retrieves configuration information about virtual servers
from a Hypervisor and notifies the system administrator if
the configuration has changed (for example, a VLAN is
added or removed). Manually enter changes in the Dell
Networking OS configuration parameters.
config
VSN retrieves configuration information from the Hypervisor
and implements any necessary configuration changes
automatically.
Defaults config
Command Modes HYPERVISOR
128
Virtual Server Networking CLI