Service Manual

00:02:56: %STKUNIT0-M:CP %BMP-5-BMP_RELEASE_HEADER_INFO:
Flash A Image Minor Version : 3
00:02:56: %STKUNIT0-M:CP %BMP-5-BMP_RELEASE_HEADER_INFO:
Flash A Image Main Version : 0
00:02:56: %STKUNIT0-M:CP %BMP-5-BMP_RELEASE_HEADER_INFO:
Flash A Image Patch Version : 57
00:02:56: %STKUNIT0-M:CP %BMP-2-BMP_DOWNLOAD_START: The Dell
Networking OS image download has started.
00:03:29: %STKUNIT0-M:CP %BMP-5-BMP_DOWNLOAD: The Dell
Networking OS image download is successful.
00:03:31: %STKUNIT0-M:CP %BMP-5-BMP_MD5_VALIDATE_SUCCESS: The
Dell Networking OS image MD5 Checksum Validation Successful.
Erasing Sseries Primary Image, please wait
If the versions match, the system downloads the conguration le or pre–conguration script.
00:03:07: %STKUNIT0-M:CP %BMP-2-BMP_DOWNLOAD_START: The config
file download has started.
00:03:19: %STKUNIT0-M:CP %BMP-5-BMP_DWNLD_FILE_IS_SCRIPT_FILE:
The downloaded file is a script file.
00:03:19: %STKUNIT0-M:CP
%BMP-5-BMP_DWNLD_CONFIG_SCRIPT_SUCCESS: The config/script file
download is successful.
00:03:21: %STKUNIT0-M:CP %BMP-5-BMP_PRE_CONFIG_SCRIPT_BEGIN:
The Pre-Config Script has started to Execute.
..
00:04:30: %STKUNIT0-M:CP %BMP-5-BMP_PRE_CONFIG_SCRIPT_END:
Pre-Config script completed with return status 0.
c If you download the conguration le or pre–conguration script from the server, the ash ignores any saved startup
conguration. If you do not download the conguration le or pre–conguration script from the server, the startup conguration
le on the ash loads in Normal reload.
8 When the Dell Networking OS build image and conguration le or pre–conguration script download, the IP address is released.
NOTE
: In the pre–conguration script, the DHCP IP address is released after the script
executes.
9 The system applies the conguration. The system is now up and running and you can manage it as usual.
10 SHA256/MD5 hash veries the integrity of the les BMP downloads. For each le, the relevant filename.sha256 or
filename.md5 must be present in the same location as the Dell Networking OS image – script or conguration le.
a When you disable FCoE initialization protocol (FIPs) mode:
If both filename.sha256 and filename.md5 are not present, the image is downloaded without validation.
If both filename.sha256 and filename.md5 are present, SHA256 validation has a higher priority compared with MD5
validation.
If filename.sha256 or filename.md5 alone is present, the corresponding type of validation is completed.
b When you enable FIPs mode:
MD5 validation is not used. BMP checks only for the filename.sha256 and not filename.md5.
If filename.sha256 is present, it uses SHA256 validation or the image downloads without SHA256 validation.
Syslog for SHA256VALIDATION success on downloading an image le and conguration/pre-script le:
00:03:07: %STKUNIT0-M:CP %BMP-5-BMP_SHA256_VALIDATE_SUCCESS: The Dell
Networking OS image SHA256 Checksum Validation Succeeded.
00:01:15: %STKUNIT0-M:CP %BMP-5-BMP_SHA256_VALIDATE_SUCCESS: The
Config/Script SHA256 Checksum Validation Succeeded.
Syslog for SHA256VALIDATION failure on downloading an image le and conguration/pre-script le:
00:03:22: %STKUNIT0-M:CP %BMP-2-BMP_SHA256_VALIDATE_FAILURE: The Dell
Networking OS image SHA256 Checksum Validation Failed.
00:03:22: %STKUNIT0-M:CP %BMP-2-BMP_SHA256_VALIDATE_FAILURE: The
Config/Script SHA256 Checksum Validation Failed.
20
Bare Metal Provisioning