Service Manual

Parameters
enable
Enables the syslog messages in the console while BMP is running.
disable
Disables the syslog messages in the console while BMP is running.
Defaults none
Command Modes EXEC
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.9(0.0) Introduced on the C9010.
9.8(2.0) Introduced on the S3100 series.
9.8(1.0P1) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048–ON.
9.8(0.0P2) Introduced on the S3048–ON.
9.7(0.0) Introduced on the S6000–ON.
9.6(0.0) Introduced on the S6000.
9.5(0.1) Introduced on the Z9500.
9.5(0.0) Introduced on the S4810, S4820T, S6000, Z9000, and MXL.
Usage Information
This command is applicable only when BMP is running and enables or disables the syslog messages (with a
Severity level >2, critical).
When BMP is not running, the following error message displays: % Error: bmp process is not
running.
NOTE: This CLI command is only available in BMP normal context, which is similar to providing the L
option in the Factory-default context.
boot-type
Allows you to congure the reload type.
S4810, S4820T, S3048–ON, S3100 series, S4048–ON, S5000,
S6000, S6000–ON, Z9100–ON, Z9500, C9010, IOA, and MXL
Syntax
boot-type { bmp-reload | normal-reload }
To reset the boot-type mode, use the no boot-type { bmp-reload | normal-reload } command.
Parameters
bmp-reload
Reloads the system in BMP mode. After performing the reload, the system retrieves the
Dell Networking OS image and startup-conguration les from the ash.
normal-reload
Reloads the system in manual interactive mode.
38 Bare Metal Provisioning CLI