Administrator Guide

reload conditional nvram-cfg-change
After saving the BMP configuration, to perform a reload on the chassis due to configuration changes that
changes the NVRAM content, use this command.
S4810, S4820T, S5000, S6000, S6000–ON, Z9000, Z9500, and MXL Switch
Syntax
reload conditional nvram-cfg-change
Defaults none
Command
Modes
EXEC
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.7(0.0) Introduced on the S6000–ON.
9.6(0.0) Introduced on the S5000.
9.5(0.1) Introduced on the Z9500.
9.3(0.0) Introduced on the S6000.
9.2(0.0) Introduced on the MXL Switch.
9.1(0.0) Introduced on the Z9000 and S4810.
8.3.19.0 Introduced on the S4820T.
Usage
Information
To upgrade any NVRAM changes to the chassis caused by the following CLI
commands, use the reload conditional nvram-cfg-change command on a
switch running BMP.
stack-unit {unit} stack-group
stack-unit {unit} port {fanout-portid} portmode quad
asf-mode
cam-acl
buffer-profile
48
Bare Metal Provisioning CLI