Administrator Guide
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.7(0.0) Introduced on the S6000–ON.
9.6(0.0) Introduced on the S5000.
9.5(0.1) Introduced on the Z9500.
9.3(0.0) Introduced on the S6000.
9.2(0.0) Introduced on the MXL switch. Updated the parameters for
S4810, S4820T, and Z9000.
9.1.0.0 Updated the parameters for S4810 and Z9000.
9.0.2.0 Introduced on the S6000.
9.0.0.0 Introduced on the Z9000.
8.3.19.0 Introduced on the S4820T.
8.3.11.4 Introduced on the Z9000.
8.3.10.0 Introduced on the S4810.
Usage
Information
To check the currently configured Auto-Configuration mode (BMP or Normal
reload) on a switch running BMP, use the show reload-type command.
To display the current reload mode for BMP, use the show bootvar or show
system brief
commands. The show bootvar command includes the path of
the Dell Networking OS image file retrieved from a DHCP server when BMP is
running, but not after you exit BMP.
Example
Dell#show reload
reload-type : bmp [Next boot : bmp]
: enable
config-scr-download : enable
dhcp-timeout : 1
vendor-class-identifier : Device 609
retry-count : 3
Dell#
Related
Commands
reload-type — allows you to configure the reload-type options in reload-type sub
command mode.
54
Bare Metal Provisioning CLI