Concept Guide
Table Of Contents
- Dell EMC Networking Open Automation Guide 9.14.1.0 November 2018
- About this Guide
- Open Automation Framework
- Bare Metal Provisioning
- Introduction
- How it Works
- Prerequisites
- Industry Standard Upgrades with BMP
- BMP Process Overview
- BMP Operations
- Configure BMP
- BMP Commands and Examples
- System Boot and Set-up Behavior in BMP Mode
- BMP Mode - Boot and Set-up Behavior
- DHCP Offer Vendor-Specific Option for BMP
- DHCP Offer Relay Option 82
- Software Upgrade Using BMP
- Apply Configurations Using BMP Scripts
- Using the Post-configuration Script
- Using Auto-Execution Script - Normal Mode Only
- Timers in Pre–configuration and Post–configuration Scripts
- Script Examples
- BMP Operations on Servers Overview
- File Server Settings
- Domain Name Server Settings
- BMP MIB Support
- Bare Metal Provisioning CLI
- Open Management Infrastructure
- Puppet
- Smart Scripting
- Overview
- Download the Smart Scripting Package
- Dell EMC Environment Variables
- Dell EMC Proprietary Utilities
- Dell EMC SmartScript Utilities
- SQLite
- NET SNMP Client
- Limits on System Usage
- Supported UNIX Utilities
- Creating a Username and Password for Smart Scripting
- Logging in to a NetBSD UNIX Shell
- Downloading Scripts to a Switch
- Network File System (NFS)
- Setting a Search Path for Scripts
- Scheduling and Executing Scripts
- Running a Script from the UNIX Shell
- Running Scripts with User Privileges
- Smart Scripting CLI
- disable
- execute
- mount nfs
- package clear-all
- package install
- package uninstall
- script (run)
- script (stop/resume/clear/kill/unschedule)
- script event-handler
- script execute (EXEC mode)
- script execute
- script get
- script path
- script remove
- script trigger-event
- show packages
- show script
- start shell
- triggered-by
- switch script limit
- username (event handler)
- username
- SNMP MIBs
- Virtual Server Networking
- Virtual Server Networking CLI
- REST API
- HTTP and HTTPS
- XML
- Important Points to Remember
- REST Authentication
- Request Query Parameters
- Sample BGP Configurations
- HTTP Status Error Codes
- REST API — Protocol Data Unit (PDU) Structure
- Configurations
- Operational
- Operational Data for IPv6
- Management Information Base (MIB)
- IETF Interface Operations
- REST API Framework to Execute the CLIs
- Samples of the config-command
- Samples of the EXEC command
- Samples of the show-command
- REST API CLI
- Web Server

Platform Bare Metal
Provisioning
(BMP)
Open
Management
Interface
(OMI)
Puppet Smart Scripts Virtual Server
Networking
(VSN)
Representatio
nal State
Transfer
Application
Programming
Interface
(REST API)
Web Server
S5048F–ON Y Y Y Y N Y Y
S6000 Y Y Y Y N Y Y
S6000–ON Y Y Y Y N Y Y
S6100–ON Y Y Y Y N Y Y
S6010–ON Y Y Y Y N Y Y
MXL Y N Y Y Y N Y
IOA Y N Y Y N N N
S3100 Series Y N N Y N N Y
Z9100–ON Y Y Y Y N Y Y
C9010 Y N N Y N Y N
FN IOM Y N Y Y N N N
Conventions
To describe command syntax, this document uses the following conventions.
Convention
Description
keyword Keywords are shown in a terminal font and are entered in the CLI as listed.
parameter Parameters are shown in italics and require you enter a number or word in the CLI.
{X} Keywords and parameters within braces require entries in the CLI.
[X] Keywords and parameters within brackets are optional.
x | y Keywords and parameters separated by bar require that you to choose one.
Related Documents
For more information about Dell EMC Networking switches described in this document, see the following documents.
Platform
Related Documents
S4810
• Dell EMC Networking OS Command Line Reference Guide for the S4810 System
• Dell EMC Networking OS Conguration Guide for the S4810 System
• Dell EMC Networking Installation Guide for the S4810 System
S4820T
• Dell EMC Networking OS Command Line Reference Guide for the S4820T System
• Dell EMC Networking OS Conguration Guide for the S4820T System
• Dell EMC Networking Installation Guide for the S4820T System
10 About this Guide