Setup Guide

Usage Information
To check the currently congured Auto-Conguration mode (BMP or Normal reload) on a switch running BMP, use
the show reload-type command.
To display the current reload mode for BMP, use the show bootvar or show system brief commands. The
show bootvar command includes the path of the Dell EMC Networking OS image le retrieved from a DHCP
server when BMP is running, but not after you exit BMP.
Example
DellEMC#show reload
reload-type : bmp [Next boot : bmp]
: enable
config-scr-download : enable
dhcp-timeout : 1
vendor-class-identifier : Device 609
retry-count : 3
DellEMC#
Related Commands
reload-type — allows you to congure the reload-type options in reload-type sub command mode.
stop bmp
To prevent an innite loop, stop the switch from reloading in BMP mode.
S4810, S4820T, S3048–ON, S3100 series, S4048–ON,
S4048T–ON, S5000, S5048F–ON, S6000, S6000–ON,
S6010–ON, S6100–ON, Z9100–ON, Z9500, C9010, , IOA, FN-
IOM, and MXL
Syntax
stop bmp
NOTE: This command replaces the stop jumpstart command.
Defaults none
Command Modes EXEC
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell EMC
Networking OS Command Line Reference Guide.
The following is a list of the Dell EMC Networking OS version history for this command.
Version Description
9.10(0.1) Introduced on the S4048T–ON and S6010–ON.
9.10(0.0) Introduced on the S6100–ON.
9.9(0.0) Introduced on the C9010.
9.8(2.0) Introduced on the S3100 series.
9.8(1.0P1) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048–ON.
Bare Metal Provisioning CLI 53