Release Notes

Known Issues
SYSCFG Issues
In DRAC 5, the --virtualmedia and --vflash options do not work if there is an active virtual media session.
Disconnect the virtual media using the DRAC GUI. Log into DRAC. Click Media > Virtual Media >
Disconnect.
The syscfg --bootseq command detects CD-ROM with SAS/SATA controllers as unk.emb.1.
On R815, syscfg power --profile option sets apc. Though apc is not supported on R815, syscfg does not
throw an error message.
On Windows PE 3.0, when you run the syscfg command to list all available options, if you press CTR + C
before the command fully executes, an error message is displayed. Click OK. You can ignore the message.
The option for "powerctl," which is "softshutdown," does not work on Windows PE.
The "--solbitrate" option in "solcfgparams" and the "--mgscommbitrate" option in "serialcfgparams"
accept a baud rate of 57600, but tools such as "ipmish" and "solproxy" do not function at that baud rate
for PowerEdge systems.
On PowerEdge 1950, 2950 and PowerVault NX 1950 systems with internal USB, BIOS setting
configuration for internal USB Port is possible only if User Accessible/external (UA) USB ports are set to
"All Ports On." If UA USB ports are not set to "All Ports On" and if you try to configure the BIOS setting for
the internal USB port using SYSCFG, the configuration will appear to be successful but the changes will
not take effect after the next reboot. If UA USB ports settings are changed from "All Ports On" to "All Ports
Off" or "Only Back Ports On," the USB port will be automatically to "Off" during the next reboot.
The legacy attribute values enable and disable are also supported for 12G systems for backward
compatibility. In future releases, these arguments might be deprecated. Try to use the values shown in
help message for BIOS options for 12G server.
DTK 4.4 does not boot on Dell PowerEdge T100. PowerEdge T100 has a BIOS version that is
incompatible with the current HAPI drivers.
RAIDCFG Issues
You can assign up to 10 Global hot spares using Raidcfg. Use the Dell OpenManage Server Administrator
Storage Management for assigning more than 10 Global hot spares.
Raidcfg does not support Non RAID (Volume) mode on s100/s300/S110 controller.
S300 controller CachePolicy setting is "Not Applicable". Hence VD created with different cachepolicy
settings from OROM utility will be displayed as "Not Applicable".
On Dell PERC H310 controllers, conversion of a RAID Capable Disk to Non-RAID disk and vice versa is not
supported using raidcfg.
RACADM Issues
If you use virtual media to boot into Windows PE, executing certain RACADM commands may cause
Windows PE to crash.
After generating the rac configuration file using the "racadm getconfig -f <file_name>" command,
comment out the following properties in the configuration file before you update a configuration using
the "racadm config -f <file_name>" command:
#cfgRacTuneCtrlEConfigDisable=0
#cfgRacTuneLocalConfigDisable=0