Quick Reference Guide

--memprefailurenotify
Valid Arguments enable, disable
Description
Enables or disables the Correctable ECC SMIs. When enabled, the
SMIs report the Correctable ECC errors.
NOTE: The equivalent option on systems prior to 12G is --
CorrEccSmi.
This option can be replicated.
Example:
A:>syscfg --memprefailurenotify=enable
memprefailurenotify=enable
Applicable Systems PowerEdge R710, R610, and T610 systems with Intel Xeon processor
--memremap
Valid Arguments
off, auto
Description
Sets the memory remapping to off or auto.
Example:
A:>syscfg --memremap=off
memremap=off
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
--mouse
Valid Arguments
on, off
Description
Turns the mouse controller on or off.
This option can be replicated.
Example:
A:>syscfg --mouse=off
mouse=off
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
--noraidprompt*
Valid Arguments
NA
Description
Specifies that the BIOS must not prompt for confirmation when
changing the mode of a RAID controller. This option can only be
used with the --embscsiraid or --embscsiraidchb options.
Without this option, the user is prompted during POST to confirm the
change of a RAID controller from RAID (SCSI) to SCSI (RAID). This
option is not replicated.
109