Quick Reference Guide

Mandatory
Options and
Arguments
Optional
Parameters
Valid Parameters
Arguments
Description
completion signal only after the data
is written to the disk.
nwc — No-Write-Caching specifies
that the controller does not send a
write-request completion signal after
the data is written to the disk.
NOTE: The -wpoption is optional
and can be added to the command
line in any order after the
mandatory option combination.
For SCSI controllers, the value of LUN
should always be 0.
For SAS controllers, the value of
enclosure can be non-zero, in which
case you must specify values for
channel, target, and enclosure.
Enumerating Array Disks
The following table lists the RAIDCFG options, parameters, and pre-defined arguments for enumerating
array disks (hard-drives).
NOTE: You can also use pdisk or -pd instead of adisk or -ad to specify an array disk.
Table 12. Enumerating Array Disks (Hard Drives)
Mandatory
Options and
Arguments
Optional
Parameters
Valid Parameters/
Arguments
Description
-ad -c=id or
adisk
controllerid=i
d
NA NA
Lists all the array disks attached to the
specified RAID controller. This option
combination is mandatory.
NOTE: The following example
displays the output of a Series 7
controller.
NOTE: The software controller does
not display the NegSpeed,
CapSpeed, Certified and
Supported parameters.
Example:
A:>raidcfg -ad -c=2
Controller: PERC H710P Adapter
****** Physical Drive ******
Vendor: DELL(tm)
Model: ST3300657SS
Protocol: SAS
Media: HDD
162