BMC Platform Events Filter Alert
Messages
All possible Platform Event Filter (PEF) Alert Messages along with a description of each event are listed in
the table below
Table 46. BMC PEF Alert Events
Event Description
Fan Probe
Failure
The fan is running too slow or not at all.
Voltage Probe
Failure
The voltage is too low for proper operation.
Discrete
Voltage Probe
Failure
The voltage is too low for proper operation.
Temperature
Probe Warning
The temperature is approaching excessively high or low limits.
Temperature
Probe Failure
The temperature is either too high or too low for proper operation.
Chassis
Intrusion
Detected
The system chassis has been opened.
Redundancy (PS
or Fan)
Degraded
Redundancy for the fans and/or power supplies has been reduced.
Redundancy (PS
or Fan) Lost
No redundancy remains for the system's fans and/or power supplies.
Processor
Warning
A processor is running at less than peak performance or speed.
Processor
Failure
A processor has failed.
PPS/VRM/DCtoDC
Warning
The power supply, voltage regulator module, or DC-to-DC converter is pending a
failure condition.
Power
Supply/VRM/D2D
Failure
The power supply, voltage regulator module, or DC-to-DC converter has failed.