Quick Reference Guide

--RedundantMem/--redmem
Valid Arguments
On systems prior to 12G
: off, spare, mirror, DDDC
On 12G and later systems
: Disabled, Spare Mode, Mirror Mode, Intra-Node Mirror Mode,
DIMM Spare Mode, Double DRAM ECC
Description
Allows selection of the required redundant memory mode, or
disables redundant memory. This option can be replicated.
Example:
A:>syscfg --redmem=off
redmem=off
Applicable Systems PowerEdge M910, R910, and R810 systems and 12G systems with
Intel Xeon 7500 series processor
--SerialDbgOut
Valid Arguments
On systems prior to 12G
:NA
On 12G and later systems
: Enabled, Disabled
Description
Enables or disables the RC/MRC Serial debug output.
Example:
A:>syscfg --SerialDbgOut=Enabled
SerialDbgOut=Enabled
Applicable Systems PowerEdge 12G and later systems.
--SysMemSize/--mem*
Valid Arguments
On systems prior to 12G
: read-only
On 12G and later systems
: read-only
Description
Displays the amount of main memory in the system.
Example:
A:>syscfg --mem
mem=500
Applicable Systems PowerEdge 11G and later systems.
--SnoopFilter/--snoopfilter
Valid Arguments
On systems prior to 12G
45