Quick Reference Guide

--TpmStatus
Valid Arguments
On systems prior to 12G
: Null
On 12G and later systems
: Null
Description
Displays the current status of TPM.
Example:
A:>syscfg --TpmStatus
Applicable Systems PowerEdge 12G and later systems
UEFI Boot Settings
You can manage the UEFI settings using the options in this group.
--UefiBootSeq
Valid Arguments
On systems prior to 12G
: NA
On 12G and later systems
: list of device names separated by commas
Description
Enables, disables, and orders the devices in a UEFI boot order list.
Only the devices present on the system are listed in the UefiBootSeq.
The first option in the list is attempted first. If the first option is not
successful, the second option is attempted, and so on. The system
attempts to launch only the enabled boot options and does not
launch disabled boot options. This option is applicable when
bootmodeis set to UEFIand has no effect when bootmode is set to
BIOS.
NOTE: Only the devices listed in the bootseq are enabled.
Applicable Systems All PowerEdge systems.
SYSCFG Options On PowerEdge Systems Prior To PowerEdge 12G Systems
The following are the valid options and arguments supported on PowerEdge systems earlier than
PowerEdge 12G systems.
--assignintr
Valid Arguments
standard, distributed
Description Controls the interrupt assignment of PCI devices in the system. This
option is set to standardby default, causing standard interrupt routing
that uses interrupt A, B, C, and D for all PCIe devices. When set to
distributed, the interrupt routing is swizzled at the MCH root ports to
minimize sharing of interrupts across all PCIe (and PCI-X in the
Programmable Interrupt Controller (PIC) mode) devices.
89