Quick Reference Guide

--embscsiraidchb
Valid Arguments raid, scsi
Description
Sets the second channel on an embedded RAID controller to SCSI or
RAID. This option is only valid for systems that support RAID/RAID
and RAID/SCSI settings for channels A and B. This option can be
replicated.
Example:
A:>syscfg --embscsiraidchb=raid
embscsiraidchb=raid
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems
--embsdcardredundancy
Valid Arguments
mirrormode, disable
Description
Sets the redundancy to mirrormode or disabled.
If set to mirrormode, read-write operation occurs on both the secure
digital (SD) cards. If one of the SD cards fails and is replaced, on
booting, the data is copied to that SD card.
If set to disable, read-write operation occurs only on SD card 1.
On Blade systems, disable the vflash key to configure this option.
Example:
A:>syscfg --embsdcardredundancy=mirrormode
embsdcardredundancy=mirrormode
Applicable Systems PowerEdge R810, R815, R910, and M910 systems
--eSataPort1
Valid Arguments
On systems prior to 12G
: NA
On 12G and later systems
: Off, Auto
Description
Sets the embedded SATA port1 to auto or off.
Example:
A:>syscfg --eSataPort1=Off
eSataPort1=Off
Applicable Systems Dell PowerEdge 12G and later systems.
--eSataPort1Capacity*
Valid Arguments
On systems prior to 12G
: NA
On 12G and later systems
96