Reference Guide

--serial1
Valid Arguments disable, com1, com3, com1_bmc, bmcserial, bmclan, rac
Description
Configures or reports the first serial port communication port. This
option can be replicated.
bmcserial — maps serial port 1 to BMC Serial.
bmclan — routes the serial traffic destined for serial1 out to NIC1.
com1_bmc — maps serial port 1 to COM port 1 BMC.
rac — maps serial port 1 to the RAC device.
Example:
A:>syscfg --serial1=rac
serial1=rac
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
--serial2
Valid Arguments
auto, disable, com2, com4
Description
Configures or reports the second serial port communication port.
This option can be replicated.
Example:
A:>syscfg --serial2=rac
serial2=rac
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
--slotname
Valid Arguments
read-only
Description
Reports the slot name of the blade.
Example:
A:>syscfg --slotname
slotname=Slot5
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
--sma
Valid Arguments
enable, disable
Description
Enables or disables processor sequential memory access.
Example:
A:>syscfg --sma=disable
sma=disable
112