Reference Guide

Option Sub-option Valid
Arguments
Description Applicable
Systems
--
alertpolstatu
s
enable,
disable
Enables or disables the alert
policy specified using the
alertpolnum sub-option.
This sub-option can be
replicated. This sub-option is
dependent on the
alertpolnum sub-option.
Example: (to set the PEF
configuration parameters):
Example 1 (To configure the
PEF so that the system is
powered down in response to
a fan failure event):
A:>syscfg pefcfgparams
--filter= fanfail--
filteraction=powerdown
pefcfgparams
filter=fanfail
filteraction=powerdown
Example 2 (To configure the
PEF so that a PEF alert is not
sent to the destination IP
address in response to a
chassis intrusion event):
A:>syscfg pefcfgparams
--filter= intrusion--
filteralert=disable
pefcfgparams filter=
intrusion
filteralert=disable
powerbutton
Option Sub-option Valid
Arguments
Description Applicable
Systems
--
powerbutton
NA
enable,
disable
Enables or disables the power
button. This option can be
replicated.
Example:
A:>syscfg --
powerbutton=enable
powerbutton=enable
All PowerEdge
systems
125