Reference Guide

--SriovGlobalEnable/--sriov
Valid Arguments
On systems prior to 12G
: enable, disable
On 12G and later systems
: Enabled, Disabled
Description
Enables or disables support for Single Root I/O Virtualization (SR-IOV)
devices.
Example:
A:>syscfg --sriov=disable
sriov=disable
Applicable Systems PowerEdge R410, R510, R610, R710, R910, T410, T610, T710, and 12G
and later systems.
--UsbPorts/--usbports
Valid Arguments
On systems prior to 12G
: enable, enablebackonly, disable
On 12G and later systems
: AllOn, OnlyBackPortsOn, AllOff
Description
Enables or disables USB ports. When set to enable, it enables all user
accessible USB ports. When set to enablebackonlyor
OnlyBackPortsOn, the front user-accessible ports are disabled.
When set to disable or AllOff, both front and back user accessible
ports are disabled. This option can be replicated.
Example:
A:>syscfg --usbports=enable
usbports=enable
Applicable Systems All PowerEdge systems.
Memory Settings
You can manage the memory-related configuration settings using the objects in this group.
--CorrEccSmi
Valid Arguments
Enabled, Disabled
Description
Enables or disables the Correctable ECC SMIs. When enabled, the
SMIs report the Correctable ECC errors.
NOTE: The equivalent option on systems prior to 12G is --
memprefailurenotify.
This option can be replicated.
42