Reference Guide

System Security
You can manage the system security properties of the BIOS using the options in this group.
--AcPwrRcvry/--acpower
Valid Arguments
On systems prior to 12G
: on, off, laste
On 12G and later systems
: On, Off, Last
Description Sets the behavior for the system after AC power is lost. This option
specifies how the system responds to the restoration of AC power
and is particularly useful in systems that are turned off using a power
strip. When set to on, the system turns on after AC is restored. When
set to
off, the system does not turn on after AC is restored. When set
to last, the system turns on if the system was on when AC power was
lost; if the system was off when AC power was lost, the system
remains off when power is restored. This option can be replicated.
Example:
A:>syscfg --acpower=on
acpower=on
Applicable Systems All PowerEdge systems.
--AcPwrRcvryDelay
Valid Arguments
On systems prior to 12G
:NA
On 12G and later systems
: Immediate, User, Random
Description
Specifies how the system supports the staggering of power-up after
AC power has been restored to the system.
Example:
A:>syscfg --AcPwrRcvryDelay=Immediate
AcPwrRcvryDelay=Immediate
Applicable Systems PowerEdge 12G and later systems
--AcPwrRcvryUserDelay
Valid Arguments
On systems prior to 12G
:NA
On 12G and later systems
: Immediate, User, Random
Description
Controls the user defined AC Recovery Delay. The delay must be in
the range of 60 seconds to 240 seconds.
82