Example:
A:>syscfg --conred=serial1
conred=serial1
Applicable Systems All PowerEdge systems prior to PowerEdge 9G systems
--coreperformanceboost
Valid Arguments enable, disable
Description
Enables or disables the AMD Core Performance Boost feature. When
enabled, it allows higher performance power states if additional
power is available to the CPU. This option can be replicated.
Example:
A:>syscfg --coreperformanceboost=enable
coreperformanceboost=enable
Applicable Systems PowerEdge R715, R815, R515, R415, and M915 systems with AMD
Opteron 6000 series processor
--dbpm
Valid Arguments
enable, disable
Description
Enables or disables demand-based power management. This option
can be replicated.
Example:
A:>syscfg --dbpm=enable
dbpm=enable
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems
--embhypervisor
Valid Arguments
off, on
Description
Turns on or off the embedded hypervisor port.
Example:
A:>syscfg --embhypervisor=on
embhypervisor=on
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems
--embideraid
Valid Arguments
on, off
Description
Turns on or off the embedded IDE RAID controller. This option is only
valid for supported systems that have IDE ROMB. This option can be
replicated.
91