Release Notes

Version affected: All
Resolution/Workaround: None. The ESXi does not support software RAID. If the system has software RAID, it shows incorrect disks.
Issue 9: System Event Logs are not showing in OpenManage Integration for VMware vCenter vSphere client when power supply
redundancy is lost.
Description: When the power redundancy is lost on the PowerEdge 12th Generation modular servers, the system logs get cleared.
Version affected: 3.0 and later
Resolution/Workaround: None
Issue 10: Memory data displays a negative value for a host after successful inventory.
Description: The Total Memory capacity displays as "0" and Memory Installable displays a negative value on the Host Memory
overview page. This issue occurs because of some issue in the iDRAC.
Version affected: All
Resolution/Workaround: Restart the system and check if the issue is resolved. If issue is not resolved, you may have to reset the
iDRAC.
Issue 11: Chassis and server health is displayed as warning on the Chassis Summary page when server becomes critical.
Description: When a critical entry is made to SEL logs, the health of the server (blade) changes to critical. This is correctly reflected on
the Host Summary page. However, this is not reflected on the Chassis Summary page. The server health is displayed as warning. If the
chassis was normal earlier, the health of the chassis also changes to warning.
Version affected: 3.0 and later
Resolution/Workaround: None. This is a known defect in the RACADM. The defect will be fixed in the next release of RACADM for
chassis.
Issue 12: The physical disk name is not displayed at data center and cluster level inventory in some situations.
Description: Although the physical disk name is displayed when you view the inventory at the host level, the physical disk name is
displayed empty when you view the inventory of the host at the data center and cluster level.
Version affected: 3.0 and later
Resolution/Workaround: This issue does not affect the functionality of the features, and you can view the inventory at the host level
to see the physical disk name.
Issue 13: Invalid data is displayed for physical disks and virtual disks at data center and cluster inventory intermittently.
Description: When you create connection profile for hosts and run an inventory for the hosts, verify the physical disk and virtual disk
information at the data center, cluster, and host level. On verification, the host level inventory displays valid data whereas in some
situations, at the data center and cluster level, invalid data is displayed along with the valid set of data.
Version affected: 3.0 and later
Resolution/Workaround: This issue is infrequent, and you can press the Refresh option in the same screen to display valid data.
Issue 14: Processor Version is not displayed for 12th generation servers on the overview firmware page of host.
Description: For 12th generation servers, processor version is not displayed on the overview page for firmware inventory. This
information is available for 11th and earlier generation systems.
Version affected: 2.0 and later
Resolution/Workaround: None
Issue 15: Hard disk option is not disabled in the Deployment wizard for all the servers that do not contain hard disk drives.
Description: While navigating through the Deployment wizard, if the bare-metal servers do not have any hard disk drive, then the hard
disk option should be disabled on the Global Settings tab. However, the option is available for selection.
Version affected: 2.0 and later
Resolution/Workaround: None
Issue 16: The Initial Configuration wizard is displayed continuously.
Description: The Initial Configuration wizard may be displayed if you click Cancel after selecting the Do not show again option. To
properly read the Do not show again option, the wizard should move to the next page.
Version affected: 2.0 and later
Resolution/Workaround: Select the Do not show again option, and then click Next to move to the next page. Click Cancel to close
the dialog box.
Issue 17: Internal Dual SD Module is disabled for a server that has Internal Dual SD Module and no Hard Disk.
4
OpenManage Integration for VMware vCenter Version 4.0 Release Notes