Owner's Manual

826 Events, Rules and Actions
-
Set Severity
The severity of the event (alarm). You can alter the default with the pick list. Any
change in severity occurs with the next occurrence of the alarm. No change occurs with what
has already been received.
-
Load MIB
You can load a MIB, if you have one available as a file.
-
Unload MIB
You can unload the MIB for the selected event if you have another to load that
better describes the event. When you unload a MIB the events in it disappear from the Event
Definitions manager unless they have previously been altered and saved. In this case such
MIB events remain with the
valid
field set to
false
. After you reload the MIB the valid field is
set back to
true
.
-
Import
Import an XML event definition.
-
Export
Export an XML event definition for the selected rule.
-
Help
Open the online help for this screen.
Detail Panels
Detail panels exist for editable text MIB Text and Advisory Text. You can also see listed
Event
Processing Rules
that use this event, and their type. Select a rule and double-click or right-click and
select
Open
to edit this rule as described in
Automation Event Processing Rule Editor on page 816
or Correlation Event Processing Rule Editor on page 819.
Finally, you can configure a message to
accompany this event with the
Event Message Template
detail panel. Click
Edit
to enter text, then
Apply
to accept it. See
MIB Browser on page 166
for instructions about how to add your own MIB.