Event Message Reference 19
Cooling Device Messages
Cooling device sensors listed in Table 2-3 monitor how well a fan is functioning. Cooling device messages 
provide status and warning information for fans in a particular chassis.
Table 2-3.  Cooling Device Messages 
Event ID Description Severity Cause
1100 Fan sensor has failed
Sensor location: 
<Location in chassis>
Chassis location: 
<Name of chassis>
Previous state was: 
<State>
Fan sensor value: 
<Reading>
Information A fan sensor in the specified 
system is not functioning. The 
sensor location, chassis location, 
previous state, and fan sensor 
value are provided.
1101 Fan sensor value unknown
Sensor location: 
<Location in chassis>
Chassis location: 
<Name of chassis>
Previous state was: 
<State>
Fan sensor value: 
<Reading>
Information A fan sensor in the specified 
system could not obtain a 
reading. The sensor location, 
chassis location, previous state, 
and a nominal fan sensor value 
are provided.
1102 Fan sensor returned to a normal value
Sensor location: 
<Location in chassis>
Chassis location: 
<Name of chassis>
Previous state was: 
<State>
Fan sensor value: 
<Reading>
Information A fan sensor reading on the 
specified system returned to a 
valid range after crossing a 
warning threshold. The sensor 
location, chassis location, 
previous state, and fan sensor 
value are provided.
1103 Fan sensor detected a warning value
Sensor location: 
<Location in chassis>
Chassis location: 
<Name of chassis>
Previous state was: 
<State>
Fan sensor value: 
<Reading>
Warning A fan sensor reading in the 
specified system exceeded a 
warning threshold. The sensor 
location, chassis location, 
previous state, and fan sensor 
value are provided.
1104 Fan sensor detected a failure value
Sensor location: 
<Location in chassis>
Chassis location: 
<Name of chassis>
Previous state was: 
<State>
Fan sensor value: 
<Reading>
Error A fan sensor in the specified 
system detected the failure of 
one or more fans. The sensor 
location, chassis location, 
previous state, and fan sensor 
value are provided.