Messages Reference Guide
Table Of Contents
- Dell OpenManage™ Server Administrator
- Messages Reference Guide
- Introduction
 - Event Message Reference
- Miscellaneous Messages
 - Temperature Sensor Messages
 - Cooling Device Messages
 - Voltage Sensor Messages
 - Current Sensor Messages
 - Chassis Intrusion Messages
 - Redundancy Unit Messages
 - Power Supply Messages
 - Memory Device Messages
 - Fan Enclosure Messages
 - AC Power Cord Messages
 - Hardware Log Sensor Messages
 - Processor Sensor Messages
 - Pluggable Device Messages
 
 - System Event Log Messages for IPMI Systems
 - Storage Management Message Reference
 - Index
 
 
 - Messages Reference Guide
 

28 Event Message Reference
Power Supply Messages
Power supply sensors monitor how well a power supply is functioning. Power supply messages listed in 
Ta ble  2-8 provide status and warning information for power supplies present in a particular chassis.
1305 Redundancy degraded
Redundancy unit: 
<Redundancy location 
in chassis>
Chassis location: 
<Name of chassis>
Previous redundancy state was: 
<State>
Warning A redundancy sensor in the 
specified system detected that 
one of the components of the 
redundancy unit has failed but 
the unit is still redundant. The 
redundancy unit location, 
chassis location, previous 
redundancy state, and the 
number of devices required for 
full redundancy are provided.
1306 Redundancy lost
Redundancy unit: 
<Redundancy location 
in chassis>
Chassis location: 
<Name of chassis>
Previous redundancy state was: 
<State>
Warning or 
Error 
(depending 
on the 
number of 
units that are 
functional)
A redundancy sensor in the 
specified system detected that 
one of the components in the 
redundant unit has been 
disconnected, has failed, or is 
not present. The redundancy 
unit location, chassis location, 
previous redundancy state, and 
the number of devices required 
for full redundancy are provided.
Table 2-8.  Power Supply Messages 
Event ID Description Severity Cause
1350 Power supply sensor has failed
Sensor location: 
<Location in chassis>
Chassis location: 
<Name of chassis>
Previous state was: 
<State>
Power Supply type: 
<type of power 
supply>
<Additional power supply status 
information>
If in configuration error state:
Configuration error type: 
<type of 
configuration error>
Information A power supply sensor in the 
specified system failed. The 
sensor location, chassis location, 
previous state, and additional 
power supply status information 
are provided.
Table 2-7.  Redundancy Unit Messages (continued)
Event ID Description Severity Cause