 - Messages Reference Guide
 

Event Message Reference 31
Fan Enclosure Messages
Some systems are equipped with a protective enclosure for fans. Fan enclosure messages listed in 
Ta ble  2-10 monitor whether foreign objects are present in an enclosure and how long a fan enclosure is 
missing from a chassis.
Table 2-9.  Memory Device Messages 
Event ID Description Severity Cause
1403 Memory device status is 
<status>
Memory device location: 
<location in 
chassis>
Possible memory module event cause: 
<list of causes>
Warning A memory device correction rate 
exceeded an acceptable value. The 
memory device status and location 
are provided.
1404 Memory device status is 
<status>
Memory device location: 
<location in 
chassis>
Possible memory module event cause: 
<list of causes>
Error A memory device correction rate 
exceeded an acceptable value, a 
memory spare bank was activated, 
or a multibit ECC error occurred. 
The system continues to function 
normally (except for a multibit 
error). Replace the memory 
module identified in the message 
during the system’s next scheduled 
maintenance. Clear the memory 
error on multibit ECC error. 
The memory device status and 
location are provided.
Table 2-10.  Fan Enclosure Messages 
Event ID Description Severity Cause
1450 Fan enclosure sensor has failed
Sensor location: 
<Location in chassis>
Chassis location: 
<Name of chassis>
Information The fan enclosure sensor in the 
specified system failed. The sensor 
location and chassis location 
are provided.
1451 Fan enclosure sensor value unknown
Sensor location: 
<Location in chassis>
Chassis location: 
<Name of chassis>
Information The fan enclosure sensor in the 
specified system could not obtain a 
reading. The sensor location and 
chassis location are provided.
1452 Fan enclosure inserted into system
Sensor location: 
<Location in chassis>
Chassis location: 
<Name of chassis>
Information A fan enclosure has been inserted 
into the specified system. The 
sensor location and chassis location 
are provided.