Event Message Reference 33
Hardware Log Sensor Messages
Hardware logs provide hardware status messages to systems management software. On certain systems, 
the hardware log is implemented as a circular queue. When the log becomes full, the oldest status 
messages are overwritten when new status messages are logged. On some systems, the log is not circular. 
On these systems, when the log becomes full, subsequent hardware status messages are lost. Hardware 
log sensor messages listed in 
Ta ble  2-12 provide status and warning information about the noncircular 
logs that may fill up, resulting in lost status messages.
1503 AC power has been lost
Sensor location: 
<Location in chassis>
Chassis location: 
<Name of chassis>
Warning An AC power cord has lost its 
power, but there is sufficient 
redundancy to classify this as a 
warning. The sensor location and 
chassis location information 
are provided.
1504 AC power has been lost
Sensor location: 
<Location in chassis>
Chassis location: 
<Name of chassis>
Error An AC power cord has lost its 
power, and lack of redundancy 
requires this to be classified as an 
error. The sensor location and 
chassis location information 
are provided.
1505 AC power has been lost
Sensor location: 
<Location in chassis>
Chassis location: 
<Name of chassis>
Error An AC power cord sensor in the 
specified system failed. The AC 
power cord status cannot be 
monitored. The sensor location 
and chassis location information 
are provided.
Table 2-12.  Hardware Log Sensor Messages 
Event ID Description Severity Cause
1550 Log monitoring has been disabled
Log type: 
<Log type>
Information A hardware log sensor in the 
specified system is disabled. The 
log type information is provided.
1551 Log status is unknown
Log type: 
<Log type>
Information A hardware log sensor in the 
specified system could not obtain a 
reading. The log type information 
is provided.
Table 2-11.  AC Power Cord Messages (continued)
Event ID Description Severity Cause