Messages Reference Guide
Table Of Contents
- Dell OpenManage™ Server Administrator
- Messages Reference Guide
- Introduction
 - Event Message Reference
- Miscellaneous Messages
 - Temperature Sensor Messages
 - Cooling Device Messages
 - Voltage Sensor Messages
 - Current Sensor Messages
 - Chassis Intrusion Messages
 - Redundancy Unit Messages
 - Power Supply Messages
 - Memory Device Messages
 - Fan Enclosure Messages
 - AC Power Cord Messages
 - Hardware Log Sensor Messages
 - Processor Sensor Messages
 - Pluggable Device Messages
 
 - System Event Log Messages for IPMI Systems
 - Storage Management Message Reference
 - Index
 
 
 - Messages Reference Guide
 

System Event Log Messages for IPMI Systems 37
System Event Log Messages for IPMI Systems
The following tables list the system event log (SEL) messages, their severity, and cause.
  NOTE: For corrective actions, see the appropriate documentation.
Temperature Sensor Events
The temperature sensor event messages help protect critical components by alerting the systems 
management console when the temperature rises inside the chassis. These event messages use 
additional variables, such as sensor location, chassis location, previous state, and temperature sensor 
value or state.
Table 3-1.  Temperature Sensor Events 
Event Message Severity Cause
<
Sensor Name/Location
> 
temperature sensor detected a 
failure <
Reading
> where <
Sensor 
Name/Location
> is the entity 
that this sensor is monitoring. 
For example, "PROC Temp" or 
"Planar Temp."
Reading is specified in degree 
Celsius. For example 100 C.
Critical Temperature of the backplane board, 
system board, or the carrier in the specified 
system <Sensor Name/Location> exceeded 
the critical threshold.
<Sensor Name/Location
> 
temperature sensor detected a 
warning <
Reading
>.
Warning Temperature of the backplane board, 
system board, or the carrier in the specified 
system <Sensor Name/Location> exceeded 
the non-critical threshold.
<
Sensor Name/Location
>
temperature sensor returned to 
warning state <
Reading
>.
Warning Temperature of the backplane board, 
system board, or the carrier in the specified 
system <Sensor Name/Location> returned 
from critical state to non-critical state.
<
Sensor Name/Location
> 
temperature sensor returned to 
normal state <
Reading
>.
Information Temperature of the backplane board, 
system board, or the carrier in the specified 
system <Sensor Name/Location> returned 
to normal operating range. 










