42 System Event Log Messages for IPMI Systems
BMC Watchdog Events
The BMC watchdog operations are performed when the system hangs or crashes. These messages 
monitor the status and occurrence of these events in a system.
Memory Events
The memory modules can be configured in different ways in particular systems. These messages monitor the 
status, warning, and configuration information about the memory modules in the system.
Table 3-7.  BMC Watchdog Events 
Event Message Severity Cause
BMC OS Watchdog timer expired. Information This event is generated when the BMC watchdog 
timer expires and no action is set.
BMC OS Watchdog performed 
system reboot.
Critical This event is generated when the BMC watchdog 
detects that the system has crashed (timer expired 
because no response was received from Host) and the 
action is set to reboot.
BMC OS Watchdog performed 
system power off.
Critical This event is generated when the BMC watchdog 
detects that the system has crashed (timer expired 
because no response was received from Host) and the 
action is set to power off.
BMC OS Watchdog performed 
system power cycle.
Critical This event is generated when the BMC watchdog 
detects that the system has crashed (timer expired 
because no response was received from Host) and the 
action is set to power cycle.
Table 3-8.  Memory Events 
Event Message Severity Cause
Memory RAID redundancy 
degraded.
Information This event is generated when there is a memory 
failure in a RAID-configured memory configuration.
Memory RAID redundancy lost. Critical This event is generated when redundancy is lost in a 
RAID-configured memory configuration.
Memory RAID redundancy regained Information This event is generated when the redundancy lost or 
degraded earlier is regained in a RAID-configured 
memory configuration.
Memory Mirrored redundancy 
degraded.
Information This event is generated when there is a memory 
failure in a mirrored memory configuration.
Memory Mirrored redundancy 
lost.
Critical This event is generated when redundancy is lost in a 