System Event Log Messages for IPMI Systems 43
Hardware Log Sensor Events
The hardware logs provide hardware status messages to the system management software. On particular 
systems, the subsequent hardware messages are not displayed when the log is full. These messages 
provide status and warning messages when the logs are full.
Drive Events
The drive event messages monitor the health of the drives in a system. These events are generated when 
there is a fault in the drives indicated.
Memory Mirrored redundancy 
regained.
Information This event is generated when the redundancy lost or 
degraded earlier is regained in a mirrored 
memory configuration.
Memory Spared redundancy 
degraded.
Information This event is generated when there is a memory 
failure in a spared memory configuration.
Memory Spared redundancy lost. Critical This event is generated when redundancy is lost in a 
spared memory configuration.
Memory Spared redundancy 
regained.
Information This event is generated when the redundancy lost or 
degraded earlier is regained in a spared 
memory configuration.
Table 3-9.  Hardware Log Sensor Events 
Event Message Severity Cause
Log full detected. Critical This event is generated when the SEL device detects 
that only one entry can be added to the SEL before it 
is full.
Log cleared. Information This event is generated when the SEL is cleared.
Table 3-10.  Drive Events 
Event Message Severity Cause
Drive <
Drive #
> asserted fault 
state.
Critical This event is generated when the specified drive in 
the array is faulty.
Drive <
Drive #
> de-asserted 
fault state.
Information This event is generated when the specified drive 
recovers from a faulty condition.
Table 3-8.  Memory Events (continued)
Event Message Severity Cause