Messages Reference Guide
Table Of Contents
- Dell OpenManage™ Server Administrator
- Messages Reference Guide
- Introduction
 - Event Message Reference
- Miscellaneous Messages
 - Temperature Sensor Messages
 - Cooling Device Messages
 - Voltage Sensor Messages
 - Current Sensor Messages
 - Chassis Intrusion Messages
 - Redundancy Unit Messages
 - Power Supply Messages
 - Memory Device Messages
 - Fan Enclosure Messages
 - AC Power Cord Messages
 - Hardware Log Sensor Messages
 - Processor Sensor Messages
 - Pluggable Device Messages
 
 - System Event Log Messages for IPMI Systems
 - Storage Management Message Reference
 - Index
 
 
 - Messages Reference Guide
 

Storage Management Message Reference 47
2050 Array disk offline Warning / 
Non-critical
Cause: A physical disk in the array is offline. 
A disk can be made offline during a "Prepare 
to Remove" operation or because a user 
manually put the disk offline. 
Action: 
Perform a rescan. You can also select 
the offline disk and perform a Make 
Online operation. 
903 502
2051 Array disk degraded Warning / 
Non-critical
Cause: An array disk has reported an error 
condition and may be degraded. The array 
disk may have reported the error condition in 
response to a consistency check or 
other operation.
Action: Replace the degraded array disk. 
You can identify which disk is degraded by 
locating the disk that has a red "X" for its 
status. Perform a rescan after replacing 
the disk.
903 503
2052 Array disk inserted Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
901 504
2053 Virtual disk created Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
1201 505
2054 Virtual disk deleted Warning / 
Non-critical
Cause: A virtual disk has been deleted. 
"Performing a Reset Configuration" operation 
may detect that a virtual disk has been 
deleted and generate this alert.
Action: None
1203 506
2055 Virtual disk 
configuration 
changed
Ok / 
Normal
Cause: This alert is provided for 
informational purposes. 
Action: None
1201 507
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number