50 Storage Management Message Reference
2070 Virtual disk 
initialization 
cancelled
Ok / 
Normal
Cause: The virtual disk initialization 
cancelled because a physical disk included in 
the virtual disk has failed or because a user 
cancelled the virtual disk initialization.
Action: If a physical disk failed, then replace 
the physical disk. You can identify which disk 
has failed by locating the disk that has a red 
“X” for its status. Perform a rescan after 
replacing the disk. Restart the format array 
disk operation. Restart the virtual 
disk initialization.
1201 532
2074 Array disk rebuild 
cancelled
Ok / 
Normal
Cause: A user has cancelled the 
rebuild operation.
Action: Restart the rebuild operation.
901 536
2076 Virtual disk check 
consistency failed
Critical / 
Failure / 
Error
Cause: An array disk included in the virtual 
disk failed or there is an error in the parity 
information. A failed array disk can cause 
errors in parity information.
Action: Replace the failed array disk. You can 
identify which disk has failed by locating the 
disk that has a red “X” for its status. Rebuild 
the array disk. When finished, restart the 
check consistency operation.
1204 538
2077 Virtual disk format 
failed.
Critical / 
Failure / 
Error
Cause: An array disk included in the virtual 
disk failed.
Action: Replace the failed array disk. You can 
identify which array disk has failed by 
locating the disk that has a red "X" for its 
status. Rebuild the array disk. When finished, 
restart the virtual disk format operation.
1204 539
2079 Virtual disk 
initialization failed
Critical / 
Failure / 
Error
Cause: An array disk included in the virtual 
disk has failed or a user has cancelled the 
initialization.
Action: If an array disk has failed, then 
replace the array disk.
1204 541
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number