 - Messages Reference Guide
 

Storage Management Message Reference 51
2080 Array disk initialize 
failed
Critical / 
Failure / 
Error
Cause: The array disk has failed or is corrupt.
Action: Replace the failed or corrupt disk. 
You can identify a disk that has failed by 
locating the disk that has a red “X” for its 
status. Restart the initialization.
904 542
2081 Virtual disk 
reconfiguration failed
Critical / 
Failure / 
Error
Cause: An array disk included in the virtual 
disk has failed or is corrupt. A user may also 
have cancelled the reconfiguration.
Action: Replace the failed or corrupt disk. 
You can identify a disk that has failed by 
locating the disk that has a red “X” for its 
status. If the array disk is part of a redundant 
array, then rebuild the array disk. When 
finished, restart the reconfiguration.
1204 543
2082 Virtual disk rebuild 
failed
Critical / 
Failure / 
Error
Cause: An array disk included in the virtual 
disk has failed or is corrupt. A user may also 
have cancelled the rebuild.
Action: Replace the failed or corrupt disk. 
You can identify a disk that has failed by 
locating the disk that has a red “X” for its 
status. Restart the virtual disk rebuild.
1204 544
2083 Array disk rebuild 
failed
Critical / 
Failure / 
Error
Cause: An array disk included in the virtual 
disk has failed or is corrupt. A user may also 
have cancelled the rebuild.
Action: Replace the failed or corrupt disk. 
You can identify a disk that has failed by 
locating the disk that has a red “X” for its 
status. Rebuild the virtual disk rebuild.
904 545
2085 Virtual disk check 
consistency 
completed
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
1201 547
2086 Virtual disk format 
completed
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
1201 548
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number