Messages Reference Guide
Table Of Contents
- Dell OpenManage™ Server Administrator
- Messages Reference Guide
- Introduction
 - Event Message Reference
- Miscellaneous Messages
 - Temperature Sensor Messages
 - Cooling Device Messages
 - Voltage Sensor Messages
 - Current Sensor Messages
 - Chassis Intrusion Messages
 - Redundancy Unit Messages
 - Power Supply Messages
 - Memory Device Messages
 - Fan Enclosure Messages
 - AC Power Cord Messages
 - Hardware Log Sensor Messages
 - Processor Sensor Messages
 - Pluggable Device Messages
 
 - System Event Log Messages for IPMI Systems
 - Storage Management Message Reference
 - Index
 
 
 - Messages Reference Guide
 

52 Storage Management Message Reference
2088 Virtual disk 
initialization 
completed
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
1201 550
2089 Array disk initialize 
completed
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
901 551
2090 Virtual disk 
reconfiguration 
completed
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
1201 552
2091 Virtual disk rebuild 
completed
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
1201 553
2092 Array disk rebuild 
completed
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
901 554
2094 Predictive Failure 
reported. If this disk is 
part of a redundant 
virtual disk, select the 
"Offline" option and 
then replace the disk. 
Then configure a hot 
spare and it will start 
the rebuild 
automatically. If this 
disk is a hot spare, 
select the "Prepare to 
Remove" option and 
then replace the disk. 
If this disk is part of a 
non-redundant disk, 
you should back up 
your data 
immediately. If the 
disk fails, you will not 
be able to recover 
the data.
Warning / 
Non-critical
Cause: The array disk is predicted to fail. 
Many array disks contain Self Monitoring 
Analysis and Reporting Technology 
(S.M.A.R.T.). When enabled, SMART 
monitors the health of the disk based on 
indications such as the number of write 
operations that have been performed on 
the disk.
Action: Replace the array disk. Even though 
the disk may not have failed yet, it is strongly 
recommended that you replace the disk. 
Review the message text for additional 
information.
903 570
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number